https://scholars.lib.ntu.edu.tw/handle/123456789/598182
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Zhang G | en_US |
dc.contributor.author | Sui X | en_US |
dc.contributor.author | Xu Y | en_US |
dc.contributor.author | Jiao Y | en_US |
dc.contributor.author | Chang J.-S | en_US |
dc.contributor.author | Lee D.-J. | en_US |
dc.contributor.author | DUU-JONG LEE | en_US |
dc.creator | Zhang G;Sui X;Xu Y;Jiao Y;Chang J.-S;Lee D.-J. | - |
dc.date.accessioned | 2022-03-22T08:26:33Z | - |
dc.date.available | 2022-03-22T08:26:33Z | - |
dc.date.issued | 2022 | - |
dc.identifier.issn | 09608524 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85123579515&doi=10.1016%2fj.biortech.2022.126677&partnerID=40&md5=45e1247622bb32f106eb28ad627519fa | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/598182 | - |
dc.description.abstract | A U-type membraneless continuous-flow bioelectrochemical system was developed to efficiently remove tetracycline and antibiotic resistance genes from synthetic wastewaters at hydraulic retention time of only eight hours. At the TC concentration of 20–80 mgL-1 in feed, the removals of tetracycline all exceeded 95%, over 60–1200 mgL-1 chemical oxygen demand, 30–150 mgL-1 NH4+-N, and at 5–25 °C, superior to the performances reported in literature. The maximum power of the BES system peaked at 0.416 Wm?3 at 20 mgL-1 TC feeding, corresponding to open circle voltage of 0.90 V and internal resistance of 799.8 Ω. The community analysis showed that the elevated TC loadings forced the predominate population to be evolved to TC-degrading consortium. The relative abundances of tetA, tetC, tetO, tetQ, and tetW in treated effluent ranged 1.20 × 10-6 to 2.60 × 10-4, revealing that the present BES reactor has superior removal efficiency of antibiotic resistance genes. ? 2022 Elsevier Ltd | - |
dc.relation.ispartof | Bioresource Technology | - |
dc.subject | Antibiotic resistance genes | - |
dc.subject | Bioelectrochemical system | - |
dc.subject | Continuous-flow | - |
dc.subject | Membrane-less | - |
dc.subject | Removal | - |
dc.subject | Tetracycline | - |
dc.subject | Chemical oxygen demand | - |
dc.subject | Effluents | - |
dc.subject | Genes | - |
dc.subject | Ion exchange | - |
dc.subject | Ion exchange membranes | - |
dc.subject | Bio-electrochemical | - |
dc.subject | Hydraulic retention | - |
dc.subject | Ion-exchange membrane | - |
dc.subject | Membraneless | - |
dc.subject | Synthetic wastewater | - |
dc.subject | ]+ catalyst | - |
dc.subject | Antibiotics | - |
dc.subject | antibiotics | - |
dc.subject | catalysis | - |
dc.subject | catalyst | - |
dc.subject | concentration (composition) | - |
dc.subject | electrochemical method | - |
dc.subject | electrode | - |
dc.subject | membrane | - |
dc.subject | pollutant removal | - |
dc.subject | antiinfective agent | - |
dc.subject | tetracycline | - |
dc.subject | antibiotic resistance | - |
dc.subject | ion exchange | - |
dc.subject | wastewater | - |
dc.subject | Anti-Bacterial Agents | - |
dc.subject | Drug Resistance, Microbial | - |
dc.subject | Ion Exchange | - |
dc.subject | Waste Water | - |
dc.title | Efficient removal of tetracycline using U-type continuous-flow bioelectrochemical system without ion exchange membrane or cathodic catalyst | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.1016/j.biortech.2022.126677 | - |
dc.identifier.pmid | 34999189 | - |
dc.identifier.scopus | 2-s2.0-85123579515 | - |
dc.relation.journalvolume | 346 | - |
item.cerifentitytype | Publications | - |
item.fulltext | no fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.openairetype | journal article | - |
item.grantfulltext | none | - |
crisitem.author.orcid | 0000-0002-8820-8097 | - |
顯示於: | 化學工程學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。