https://scholars.lib.ntu.edu.tw/handle/123456789/611947
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Kuo J.-N. | en_US |
dc.contributor.author | Chen W.-L. | en_US |
dc.contributor.author | Jywe W.-Y. | en_US |
dc.contributor.author | Wen-Yuh Jywe | en_US |
dc.creator | Kuo J.-N.;Chen W.-L.;Jywe W.-Y. | - |
dc.date.accessioned | 2022-05-24T06:26:42Z | - |
dc.date.available | 2022-05-24T06:26:42Z | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 0256307X | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-68949201651&doi=10.1088%2f0256-307X%2f26%2f8%2f088501&partnerID=40&md5=8528f31d9ba7838aee3bbe256a6f9d9b | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/611947 | - |
dc.description.abstract | We present a bio-detection system integrated with an adjustable micro-concave mirror. The bio-detection system consists of an adjustable micro-concave mirror, micro flow cytometer chip and optical detection module. The adjustable micro-concave mirror can be fabricated with ease using commercially available MEMS foundry services (such as multiuser MEMS processes, MUMPs) and its curvature can be controlled utilizing thermal or electrical effects. Experimental results show that focal lengths of the micro-concave mirror ranging from 313.5 to 2275.0 μm are achieved. The adjustable micro-concave mirror can be used to increase the efficiency of optical detection and provide a high signal-to-noise ratio. The developed micro-concave mirror is integrated with a micro flow cytometer for cell counting applications. Successful counting of fluorescent-labeled beads is demonstrated using the developed method. ? 2009 Chinese Physical Society and IOP Publishing Ltd. | - |
dc.relation.ispartof | Chinese Physics Letters | - |
dc.subject.other | Flow measurement; Flowmeters; Signal to noise ratio; Biodetection; Concave mirror; Detection modules; Detection system; Electrical effects; MEMS process; Micro flow cytometers; Multiusers; Optical detection; Thermal; Mirrors | - |
dc.title | Surface micromachined adjustable micro-concave mirror for bio-detection applications | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.1088/0256-307X/26/8/088501 | - |
dc.identifier.scopus | 2-s2.0-68949201651 | - |
dc.relation.journalvolume | 26 | - |
dc.relation.journalissue | 8 | - |
item.cerifentitytype | Publications | - |
item.openairetype | journal article | - |
item.fulltext | no fulltext | - |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
crisitem.author.dept | Mechanical Engineering | - |
crisitem.author.parentorg | College of Engineering | - |
顯示於: | 機械工程學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。