https://scholars.lib.ntu.edu.tw/handle/123456789/624719
標題: | Comparison of k-wire insertion using oscillatory and unidirectional drilling modes under constant thrust force | 作者: | Chen L Li A.D.R Symonds C Holmes J.R Weick J.W. DIAN-RU LI |
關鍵字: | drilling mode; energy consumption; heat generation; Kirschner wire; thrust force | 公開日期: | 2022 | 卷: | 40 | 期: | 6 | 起(迄)頁: | 1301-1311 | 來源出版物: | Journal of Orthopaedic Research | 摘要: | Heat generation during the Kirschner wire (K-wire) insertion process, under either unidirectional or oscillatory drilling mode, places bone at risk of thermal osteonecrosis which can lead to infection. There is a lack of quantitative understanding of the heat generation difference between the two drilling modes and knowledge of optimal thrust force level under each mode is missing. The goal of this study is to investigate the effects of drilling modes and thrust force levels on the bone drilling outcomes. Controlled machine-based constant thrust force K-wire insertion experiments were conducted with key process parameters monitored and compared quantitatively. Statistical analysis showed that the oscillatory mode consumed 2.6 times more electricity than the unidirectional mode but generated 53% less thermal energy and 23% lower peak temperature. However, the oscillation also led to 18% higher peak torque in the transient drilling stage and 23% shallower drilling depth. The optimal choice of the drilling mode depends on specific surgical needs to minimize bone damage (control of peak temperature vs. exposure time and torque control). Heat generation was dominated by the torque and corresponding rotational power under both modes. To minimize the bone temperature while keeping high drilling speed efficiency, a moderate thrust force is preferred under the unidirectional mode to balance between feed force and compressed debris resistance. For oscillatory mode, a small thrust force to keep the K-wire engaged with the bone is optimal. © 2021 Orthopaedic Research Society. Published by Wiley Periodicals LLC. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85113144490&doi=10.1002%2fjor.25163&partnerID=40&md5=f3bcf747bb1a32b8278b7dda287da2b4 https://scholars.lib.ntu.edu.tw/handle/123456789/624719 |
ISSN: | 07360266 | DOI: | 10.1002/jor.25163 | SDG/關鍵字: | adult; animal tissue; Article; bone injury; bovine; clinical outcome; controlled study; electricity; energy consumption; force; heat; human; human tissue; machine; nonhuman; oscillation; temperature; torque; velocity; bone wire; orthopedic surgery; Bone Wires; Hot Temperature; Orthopedic Procedures; Temperature; Torque |
顯示於: | 機械工程學系 |