陳瑤明臺灣大學:機械工程學研究所葉芳伸Yeh, Fang-ShenFang-ShenYeh2007-11-282018-06-282007-11-282018-06-282006http://ntur.lib.ntu.edu.tw//handle/246246/60975本文建立一套噴柱面積與發熱面積比例等於1的實驗系統,討論噴柱在停滯區的熱傳現象,並以實驗數據導得臨界熱通量預測式。本實驗以控制熱通量的方式做穩態量測,變化參數有:發熱直徑尺寸(4mm、6mm、8mm);過冷度(20℃、30℃);噴柱速度(0.5m/s、1.0m/s、2.0m/s)。藉由各參數變化,瞭解噴柱沸騰在不同沸騰區域的熱傳機制。另外,本實驗於發熱尺寸8mm、過冷度30℃、噴柱速度2.0m/s下測得最大臨界熱通量測得值為522W/cm2相對表面過熱度37℃。最後,更進一步藉由前人的基礎,並以本文實驗數據導出臨界熱通量的預測式,誤差在±15%以內。We construct an experiment system to investigate the heat transfer phenomenon at the stagnation region of an impinging jet with a unitary ratio of jet cross section and heat transfer area. Thereafter, a critical heat flux equations deduced from the experimental results was obtained. All experiment data was measured in steady state. Experiments were carried out at heat transfer surface diameters of 4~8mm, jet velocities of 0.5~2.0m/s and liquid subcooling of 20℃ and 30℃. With the parameter varying, we can interpret the heat transfer mechanism in each boiling region. Besides, the maximum CHF and wall superheat were 522W/cm2 and 37℃, recorded at heat transfer surface diameter of 8mm,jet velocity of 2.0m/s and liquid subcooling of 30℃. Finally, we deduce an equation to forecast the critical heat flux in jet stagnation region within a 15% error.中文摘要 i 英文摘要 ii 目錄 iii 圖目錄 v 表目錄 vi 符號說明 vii 第一章 緒論 1 1.1前言 1 1.2文獻回顧 5 1.2.1池沸騰文獻 5 1.2.2強制對流沸騰文獻 6 1.2.3奈米流體熱傳文獻 7 1.3研究目的 10 第二章 實驗原理 11 2.1噴柱沸騰 11 2.2臨界熱通量的判定 13 第三章 實驗設備與步驟 16 3.1實驗設計 16 3.2實驗設備 16 3.2.1主測試循環系統 16 3.2.2溫控及冷卻系統 21 3.2.3程式介面與溫度紀錄系統 21 3.3實驗步驟 24 3.3.1實驗硬體的架設 24 3.3.2實驗前的預備 24 3.3.3實驗步驟 25 3.4誤差分析 27 第四章 實驗結果與分析 31 4.1典型停滯區噴柱沸騰曲線 31 4.2噴柱速度的影響 35 4.3液體過冷度的影響 39 4.4發熱面尺寸的影響 43 4.5 臨界熱通量的預測 47 第五章 結論與建議 52 5.1結論 52 5.2建議 53 參考文獻 54 附錄 581482854 bytesapplication/pdfen-US噴柱臨界熱通量沸騰熱傳停滯區對流JetCritical heat fluxboiling heat transferstagnation zone force convection噴柱沸騰之熱傳研究Investigation of the Impinging Jet Boiling Heat Transferthesishttp://ntur.lib.ntu.edu.tw/bitstream/246246/60975/1/ntu-95-R91522316-1.pdf