國立臺灣大學電機工程學系暨研究所許源浴2006-07-252018-07-062006-07-252018-07-062003-07-31http://ntur.lib.ntu.edu.tw//handle/246246/7930本計畫之主要目的在利用靜態同步調相器,以改善台電系統之穩態電壓與動態電壓響應進 而使系統遠離電壓崩潰點。台電系統電壓,長期以來一直受到因各區域的發電量與負載量不平衡 情形使峨眉匯流排電壓偏低,更有可能在系統處於尖峰負載狀況下,因為負載劇烈變化產生擾動 造成整個輸電系統的不穩定。因此,在第一年計畫中,我們以補償器對峨眉匯流排電壓及其負載 的提升率為參考指標,決定出靜態同步調相器的組態、裝設容量,以期能使此系統在最差的N-1 的跳線情況下,穩態時仍能維持各匯流排電壓在0.95 p.u.以上,在第一年的計畫中並同時探討系 統的動態響應,在正常運轉及線路跳脫時,加入靜態同步調相器下,當系統發生擾動時峨眉超高 壓匯流排的動態電壓響應。The purpose of this project is to examine the feasibility of applying static synchronous compensators (STATCOMs) to improve the dynamic voltage response of Taiwan power system. The longitudinal power system in Taiwan suffers from two major problems, i.e., the area generation-load unbalance in the three areas and the disproportionate power flows over the two existing parallel corridors. Consequently, low voltage profiles have been observed on O-MEI bus for the system under normal operation or under some outage conditions. It is thus necessary to devise some proper means to improve the O-MEI bus voltage to prevent the system from voltage instability. Besides, it is also important to improve the dynamic voltage responses under sidturbance conditions. In the present work, STATCOMs will be employed to promote steady-state voltages and to improve the dynamic voltage responses on O-MEI bus. In phase 1 of this three-year project, the steady-state voltage profiles and dynamic voltage responses of O-MEI bus after STATCOMs are installed will be analyzed. The effect of the capacities of STATCOMs on steady-state voltage will be investigated.application/pdf537165 bytesapplication/pdfzh-TW國立臺灣大學電機工程學系暨研究所靜態同步調相器動態電壓響應無效電力補償static synchronous compensators (STATCOMs)dynamic voltage responsereactive power compensation用於電力系統電壓控制之原型靜態同步調相器之研究(1/3)A prototype static synchronous compensator for power system voltage controlreporthttp://ntur.lib.ntu.edu.tw/bitstream/246246/7930/1/912213E002114.pdf