單秋成江家慶2021-11-042021-11-04200600304018https://scholars.lib.ntu.edu.tw/handle/123456789/586350https://www.scopus.com/inward/record.uri?eid=2-s2.0-28544440391&doi=10.1016%2fj.optcom.2005.07.046&partnerID=40&md5=56f3dc1fd8657a89438a9fba75afb87dThe performance of long period fiber grating (LPFG) sensors written in single cladding and double cladding fibers have been compared by using a fast responding interrogation system based on intensity modulation. Temperature and dynamic strain monitoring using this system have been demonstrated. This system is capable of resolving strain to 0.2 and 0.4 με at a loading frequency of 20 Hz, and temperature resolution to 0.02 and 0.19 °C by using LPFG in the single cladding (SC-LPFG) and double cladding (DC-LPFG), respectively. © 2005 Elsevier B.V. All rights reserved.Fiber Bragg gratings; Intensity modulation; Long period fiber grating; Optical fiber sensor[SDGs]SDG7Cladding (coating); Optical sensors; Strain; Intensity modulation; Long period fiber grating (LPFG); Optical fiber sensor; Fiber Bragg gratingsComparison of Single and Double Cladding Long Period Fiber Grating Sensor using an Intensity Modulation Interrogation Systemjournal article10.1016/j.optcom.2005.07.0462-s2.0-28544440391