https://scholars.lib.ntu.edu.tw/handle/123456789/411456
Title: | A compact and fast temperature-response heat pump water heater | Authors: | Huang B.J. Lin F.H. |
Issue Date: | 1997 | Publisher: | American Society of Mechanical Engineers (ASME) | Source: | ASME Turbo Expo | Abstract: | A compact and fast temperature-response heat pump water heater was designed using multiple tanks and a sequential control device. The supply tank was heated as a priority by a freon-line switching device to increase the temperature recovery speed. A dual-tank prototype with 100- liter capacity was built and tested. The experimental results show that the time for temperature recovery of the supply tank from 42°C to 54°C reaches 10-20 minutes and COP reaches 2.0-3.0 during various seasons. The prototype tests show that an energy saving around 50%-70% as compared to the electrical water heater can be obtained. The hot water discharge efficiency of the heat pump is 0.912. Copyright © 1997 by ASME. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84928494281&doi=10.1115%2f97-AA-026&partnerID=40&md5=f8481c583023d94af77c789e7e0902cd https://scholars.lib.ntu.edu.tw/handle/123456789/411456 |
ISBN: | 9.78079E+12 | DOI: | 10.1115/97-AA-026 | SDG/Keyword: | Energy conservation; Hot water distribution systems; Pumps; Solar water heaters; Tanks (containers); Water heaters; Electrical water heater; Heat pump water heater; Heat pumps; Line switching; Prototype tests; Sequential control; Temperature recovery; Temperature response; Heat pump systems |
Appears in Collections: | 機械工程學系 |