Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Electrical Engineering and Computer Science / 電機資訊學院
  3. Electrical Engineering / 電機工程學系
  4. The value of defibrillator electrograms for recognition of clinical ventricular tachycardias and for pace mapping of post-infarction ventricular tachycardia
 
  • Details

The value of defibrillator electrograms for recognition of clinical ventricular tachycardias and for pace mapping of post-infarction ventricular tachycardia

Journal
Journal of the American College of Cardiology
Journal Volume
56
Journal Issue
12
Date Issued
2010-09-14
Author(s)
Yoshida, Kentaro
TZU YU LIU  
Scott, Clayton
Hero, Alfred
Yokokawa, Miki
Gupta, Sanjaya
Good, Eric
Morady, Fred
Bogun, Frank
DOI
10.1016/j.jacc.2010.04.043
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/635973
URL
https://api.elsevier.com/content/abstract/scopus_id/77956522269
Abstract
Objectives The purpose of this study was to assess the value of implantable cardioverter-defibrillator (ICD) electrograms (EGMs) in identifying clinically documented ventricular tachycardias (VTs). Background Twelve-lead electrocardiograms (ECG) of spontaneous VT often are not available in patients referred for catheter ablation of post-infarction VT. Many of these patients have ICDs, and the ability of ICD EGMs to identify a specific configuration of VT has not been described. Methods In 21 consecutive patients referred for catheter ablation of post-infarction VT, 124 VTs (mean cycle length: 393 ± 103 ms) were induced, and ICD EGMs were recorded during VT. Clinical VT had been documented with 12-lead ECGs in 15 of 21 patients. The 12-lead ECGs of the clinical VTs were compared with 64 different inducible VTs (mean cycle length: 390 ± 91 ms) to assess how well the ICD EGMs differentiated the clinical VTs from the other induced VTs. The exit site of 62 VTs (mean cycle length: 408 ± 112 ms) was identified by pace mapping (10 to 12 of 12 matching leads). The spatial resolution of pace mapping to identify a VT exit site was determined for both the 12-lead ECGs and the ICD EGMs using a customized MATLAB program (version 7.5, The MathWorks, Inc., Natick, Massachusetts). Results Analysis of stored EGMs by comparison of receiver-operating characteristic curve cutoff values accurately distinguished the clinical VTs from 98% of the other inducible VTs. The mean spatial resolution of a 12-lead ECG pace map for the VT exit site was 2.9 ± 4.0 cm2 (range 0 to 17.5 cm2) compared with 8.9 ± 9.0 cm2 (range 0 to 35 cm2) for ICD EGM pace maps. The spatial resolution of pace mapping varied greatly between patients and between VTs. The spatial resolution of ICD EGMs was <1.0 cm2 for <1 of the target VTs in 12 of 21 patients and 19 of 62 VTs. By visual inspection of the ICD EGMs, 96% of the clinical VTs were accurately differentiated from previously undocumented VTs. Conclusions Stored ICD EGMs usually are an accurate surrogate for 12-lead ECGs for differentiating clinical VTs from other VTs. Pace mapping based on ICD EGMs has variable resolution but may be useful for identifying a VT exit site. © 2010 American College of Cardiology Foundation.
Subjects
ICD electrograms | pace mapping | post-infarction VT
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science