Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Medicine / 醫學院
  3. National Taiwan University Hospital / 醫學院附設醫院 (臺大醫院)
  4. Pullout strength of different pedicle screws after primary and revision insertion: an in vitro study on polyurethane foam
 
  • Details

Pullout strength of different pedicle screws after primary and revision insertion: an in vitro study on polyurethane foam

Journal
BMC musculoskeletal disorders
Journal Volume
24
Journal Issue
1
Date Issued
2023-11-07
Author(s)
Wu, Lien-Chen
Hsieh, Yueh-Ying
FON-YIH TSUANG  
Kuo, Yi-Jie
Chen, Chia-Hsien
Chiang, Chang-Jung
DOI
10.1186/s12891-023-07015-3
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/639375
URL
https://api.elsevier.com/content/abstract/scopus_id/85175829794
Abstract
Background: Surgeons are routinely required to remove loose or failed pedicle screws and insert a new screw in their place. However, inserting a new screw into an existing hole may compromise the holding capacity of the pedicle screw. The purpose of this study is to evaluate the pullout strength of pedicle screws with different thread designs after the primary insertion and revision surgery in a synthetic bone model.

Methods: Four pedicle screws with different thread designs (single-lead-thread (SLT) screw, dual-lead-thread (DLT) screw, mixed-single-lead-thread (MSLT) screw, and proximal-unthreaded-dual-thread (PUDL) screw) were inserted into pre-drilled, untapped holes (ø 4.2 mm, length 35 mm) in Sawbone blocks of density 20 pcf. In the first sequence, a 6.0 mm screw was inserted into the predrilled foam block and the primary pullout strength of the screw was measured according to ASTM F543. In the second sequence, a 6.0 mm screw was inserted and removed, and then either a 6.5 mm screw of the same design or a different screw design was inserted into the same hole and the pullout strength recorded.

Results: In the first sequence, the mean pullout strength of the MSLT screw was significantly (p < 0.05) greater than all other screw designs. In the second sequence, when the MSLT screw was the primary screw, using a larger MSLT screw (6.5 mm) as the revision screw did not lead to a higher pullout strength than if a 6.0 mm diameter PUDL screw was used for the revision. Using a larger DLT screw (6.5 mm) as the revision screw resulted in a significantly (p < 0.05) greater pullout strength than a 6.0 mm STL, DLT, MSLT, or PUDL screw.

Conclusions: Our results indicate that employing classic oversizing of the same screw design is a safe choice for maintaining screw purchase in the bone after revision. In cases where oversizing with the same screw design is not practical, opting for a PUDL screw with the same original diameter can provide enough purchase in the bone to maintain stability.
Subjects
Biomechanics
Pedicle screw
Pullout strength
Screw thread
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science