標題: | ECG triggering and gating for ultrasonic small animal imaging | 作者: | J.-H. Liu G.-S. Jeng T.-K. Wu P.-C. Li PAI-CHI LI |
公開日期: | 九月-2006 | 卷: | 53 | 期: | 9 | 起(迄)頁: | 1590- 1596 | 來源出版物: | IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control | 摘要: | Echocardiography (ECG) is routinely used in the clinical diagnosis of cardiac function. The anatomy of the mouse is similar to that of the human, and thus murine ECG has become an effective tool for the assessment of small animal models of human cardiac diseases. Unfortunately, clinical ultrasonic imaging systems are not suitable for murine cardiac imaging due to their limited spatial and temporal resolutions. Murine ECG requires a spatial resolution better than 100 μm, which mandates the use of high-frequency, ultrasonic imaging (i.e., > 20 MHz). High-frequency transducer arrays currently are not available, and so such systems use the mechanical scanning of a single-element transducer for which the frame rate is insufficient for directly monitoring the rapid beating of a mouse heart, and thus retrospective image reconstruction is necessary. This paper presents a high-frequency, ultrasonic imaging system for murine cardiac imaging. Two scanning methods have been developed. One is based on ECG triggering and is called the block scanning mode, in which the murine cardiac images from the isovolumic contraction and isovolumic relaxation phases are retrospectively reconstructed within a relatively short data acquisition time using the ECG R-wave as the trigger to the imaging system. The other method is the line scanning mode based on ECG gating, in which both ECG and ultrasound scan lines are continuously acquired over a longer time, enabling images during the entire cardiac cycle to be obtained. It is demonstrated here that the effective frame rate is determined by the pulse repetition frequency and can be up to 2 kHz in the presented system. ? 2006 IEEE. |
URI: | http://scholars.lib.ntu.edu.tw/handle/123456789/325815 | DOI: | 10.1109/TUFFC.2006.1678187 | SDG/關鍵字: | Cardiac diseases; Cardiac imaging; Single-element transducer; Data acquisition; Image reconstruction; Medical imaging; Optical resolving power; Transducers; Ultrasonic applications; Electrocardiography; animal; animal disease; article; artifact; echocardiography; electrocardiography; equipment; equipment design; evaluation; image enhancement; image quality; instrumentation; methodology; mouse; movement (physiology); reproducibility; sensitivity and specificity; Animals; Artifacts; Echocardiography; Electrocardiography; Equipment Design; Equipment Failure Analysis; Image Enhancement; Mice; Movement; Phantoms, Imaging; Reproducibility of Results; Sensitivity and Specificity |
顯示於: | 電機工程學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。