Abstract
This paper proposes the design of a passive micromixer that utilizes the self-circulation of the fluid in the mixing chamber for applications in the Micro Total Analysis Systems (£gTAS). The micromixer with a total volume of about 20 £gL and consisting of an inlet port, a circular mixing chamber and an outlet port was designed. The device was actuated by a pneumatic pump to induce self-circulation of the fluid. The self-circulation phenomenon in the micromixer was predicted by the computational simulation of the microfluidic dynamics. Flow visualization with fluorescence tracer was used to verify the numerical simulations and indicated that the simulated and the experimental results were in good agreement. Besides, an index for quantifying the mixing performance was employed to compare different situations and to demonstrate the advantages of the self-circulation mixer. The mixing efficiencies in the mixer under different Reynolds numbers (Re) were evaluated numerically. The numerical results revealed that the mixing efficiency of the mixer with self-circulation was 1.7 to 2 times higher than that of the straight channel without a mixing chamber at Re = 150. When Re was as low as 50, the mixing efficiency of the mixer with self-circulation in the mixing chamber was improved approximately 30% higher than that in the straight channel. The results indicated that the self-circulation in the mixer could enhance the mixing even at low Re. The features of simple mixing method and fabrication process make this micromixer ideally suitable for £gTAS applications.
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science