Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Engineering / 工學院
  3. Mechanical Engineering / 機械工程學系
  4. Bubble pump in a closed-loop system for electronic cooling
 
  • Details

Bubble pump in a closed-loop system for electronic cooling

Journal
Applied Thermal Engineering
Journal Volume
51
Journal Issue
1-2
Pages
425-434
Date Issued
2013
Author(s)
Kuo, S.-C.
Shih, C.-C.
Chang, C.-C.
Chen, S.-L.
SIH-LI CHEN  
DOI
10.1016/j.applthermaleng.2012.06.055
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/448355
URL
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84867743381&doi=10.1016%2fj.applthermaleng.2012.06.055&partnerID=40&md5=5a14618742c09ff38937934cf6beec5d
Abstract
This study experimentally and theoretically investigates bubble pump performance in a closed-loop system for electronic cooling. The system consists of a vertical flat evaporator acting as a bubble pump, a condenser, a rising tube, a falling tube and a reservoir, and is completely filled with working fluid. As the bubble pump absorbs heat, the differences in the working fluid density between the rising and falling tubes induce flow motion. The effects of the input heating power, the pump inlet temperature and the boiling surfaces are determined experimentally. There are three heat-transfer regions inside the pump, including natural convection, subcooled boiling and saturated boiling. A theoretical pressure drop model and a thermal resistance network are constructed to describe the performance of the bubble pump. The results indicate that the bubble pump performs better at saturated boiling conditions. When the pump inlet temperature is the saturated temperature, the maximum flow rate is 200 ml/min at 30 W and the maximum driving pressure of the pump is 962 Pa at 80 W. The results also show that the sudden contraction between the pump and the rising tube, inducing a pressure drop, will reduce the system flow rate. In addition, the results demonstrate that the fins on the boiling surface can effectively diminish the center temperature of the basic plate of the pump and of pump resistance. © 2012 Published by Elsevier Ltd. All rights reserved.
SDGs

[SDGs]SDG7

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science