Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Medicine / 醫學院
  3. Medical Device and Imaging / 醫療器材與醫學影像研究所
  4. Validation of diffusion spectrum magnetic resonance imaging with manganese-enhanced rat optic tracts and ex vivo phantoms
 
  • Details

Validation of diffusion spectrum magnetic resonance imaging with manganese-enhanced rat optic tracts and ex vivo phantoms

Journal
NeuroImage
Journal Volume
19
Journal Issue
3
Pages
482-495
Date Issued
2003
Author(s)
Lin C.-P.
Wedeen V.J.
Chen J.-H.
Yao C.
WEN-YIH TSENG  
DOI
10.1016/S1053-8119(03)00154-X
URI
https://www.scopus.com/inward/record.uri?eid=2-s2.0-0043172480&doi=10.1016%2fS1053-8119%2803%2900154-X&partnerID=40&md5=bed3c621269ddb90dfcddaf7402b54bb
https://scholars.lib.ntu.edu.tw/handle/123456789/468820
Abstract
Diffusion spectrum imaging (DSI) has been demonstrated to resolve crossing axonal fibers by mapping the probability density function of water molecules diffusion at each voxel. However, the accuracy of DSI in defining individual fiber orientation and the validity of Fourier relation under finite gradient pulse widths are not assessed yet. We developed an ex vivo and an in vivo model to evaluate the error of DSI with gradient pulse widths being relatively short and long, respectively. The ex vivo model was a phantom comprising sheets of parallel capillaries filled with water. Sheets were stacked on each other with capillaries crossed at 45 degrees or 90 degrees. High-resolution T2-weighted images (T2WI) of the phantom served as a reference for the orientation of intersecting capillaries. In the in vivo model, manganese ions were infused into rats' optic tracts. The optic tracts were enhanced on T1-weighted images (T1WI) and served as a reference for the tract orientation. By comparing DSI with T2WI, the deviation angles between the primary orientation of diffusion spectrum and the 90 degrees and 45 degrees phantoms were 1.19 degrees +/- 4.82 degrees and -0.71 degrees +/- 4.91 degrees, respectively. By comparing DSI with the T1WI of rat optic tracts, the deviation angle between primary orientation of diffusion spectrum and optic tracts was -0.41 degrees +/- 6.18 degrees. In addition, two sequences of DSI using short and long gradient pulses were performed in a rat brain. The bias of the primary orientation between these two sequences was approximately 10 degrees. In conclusion, DSI can resolve crossing fiber orientation accurately. The effect of finite gradient pulse widths on the primary orientation is not critical.
SDGs

[SDGs]SDG6

Publisher
Academic Press Inc.
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science