Simultaneous dobutamine stress echocardiography and thallium-201 perf usion imaging for the detection of coronary artery disease
Journal
Cardiology (Switzerland)
Journal Volume
88
Journal Issue
6
Pages
556-562
Date Issued
1997
Author(s)
Abstract
To compare the diagnostic value of dobutamine stress echocardiography with dobutamine thallium-201 single-photonemission computed tomography (SPECT) in detecting coronary artery disease, we performed both tests simultaneously on 93 patients who also underwent coronary arteriography. Dobutamine was infused at rates of 5, 10, 20, 30 and 40 ?g/kg/min in 3-min stages. The left ventricle was divided into anteroseptal, posterolateral and inferior regions. Within each region, wall motion or perfusion abnormalities were classified as normal, ischemia or fixed defect. The response to stress was concordantly classified by both tests in 67 patients (72%, k = 0.48). Regional agreement for abnormalities was observed in 79% (k = 0.56) of the 279 regions analyzed. Dobutamine echocardiography detected 62 (93%) and thallium SPECT 60 (90%, p = NS) of the 67 patients with significant coronary artery disease (= 50% diameter stenosis). The specificity was 77 (20 of 26) and 81% (21 of 26), respectively. The accuracy was 88 and 87%, respectively. Combined the two tests gave a sensitivity of 97%, a specificity of 65% and an accuracy of 88%. The accuracy for detecting individual coronary stenosis with echocardiography was 83% for the left anterior descending artery, 84% for the right coronary artery and 73% for the left circumflex artery. With SPECT, it was 83, 87 and 76%, respectively. In conclusion, dobutamine stress echocardiography and thallium SPECT provide a comparable accuracy for detection and localization of coronary artery disease, and for identification of regional myocardial abnormalities. Performing the two tests simultaneously is feasible but it adds limited value in detecting coronary artery disease. ? 1997 S. Karger AG, Basel.
Subjects
Coronary artery disease; Dobutamine stress echocardiography; Dobutamine thallium-201 scintigraphy
SDGs
Other Subjects
dobutamine; thallium 201; accuracy; adult; aged; angiocardiography; article; clinical trial; coronary artery disease; coronary artery obstruction; diagnostic value; echocardiography; female; heart left ventricle; heart left ventricle wall motion; human; intermethod comparison; major clinical study; male; priority journal; right coronary artery; single photon emission computer tomography
Type
journal article