標題: | Acoustic Emission-Feedback Planar Ultrasound System for Localized Blood–Brain Barrier Opening Monitoring | 作者: | Tsai, Chih Hung Chen, Ko Ting Lin, Yu Xian Lin, Yu Chien WEN-SHIANG CHEN Inserra, Claude Liu, Hao Li CH Tsai KT Chen YX Lin YC Lin WS Chen C Inserra HL Liu HAO-LI LIU |
關鍵字: | Acoustic emission feedback | Blood–brain barrier | Passive cavitation detection | Planar ultrasound | 公開日期: | 13-六月-2019 | 出版社: | SPRINGER HEIDELBERG | 卷: | 39 | 期: | 3 | 起(迄)頁: | 277 | 來源出版物: | Journal of Medical and Biological Engineering | 摘要: | © 2018, Taiwanese Society of Biomedical Engineering. Transcranial pulsed ultrasound with microbubbles has been shown to temporally open the blood–brain barrier (BBB) to allow therapeutic agents to penetrate into the CNS for improved therapeutic efficacy. Recent studies have shown the feasibility of using passive cavitation detection (PCD) for monitoring or real-time control of the BBB opening in a focused ultrasound device. Planar ultrasound has unique advantages including the capability to create larger BBB openings in a single exposure, simple operation, and reduced reliance on medical imaging for sonication guidance. This study proposes a novel planar ultrasound apparatus design that can provide real-time analysis for ultrasound BBB opening monitoring. In-vitro tube phantom experiments were conducted to characterize the dependence of the energy spectrum density (ESD) change with microbubble infusion. In-vivo experiments characterized the dependence of ESD change on BBB opening. We showed that the proposed configuration provide superior ESD detection than traditional water-immersed PCD arrangement and can well correlated with the cavitation activity either in the in vitro or in vivo measurement. The ESD response corresponds well to the occurrence of BBB-opening. In animal groups which demonstrated successful BBB-opening, the peak ESD was significantly higher (12.22 ± 7.019 and 14.763 ± 11.812 dB in 0.332 and 0.463-MPa exposure). The 5-dB ESD level was found to be a valid threshold level to discriminate between the BBB-intact and BBB-opened groups to provide both high detection sensitivity (100%) and specificity (88%). These results may facilitate the design of a planar ultrasound treatment apparatus for BBB opening and drug delivery to the brain. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/480864 | ISSN: | 16090985 | DOI: | 10.1007/s40846-018-0406-x |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。