Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Medicine / 醫學院
  3. School of Medicine / 醫學系
  4. Pulse energy as a reliable reference for twitch forces induced by transcutaneous neuromuscular electrical stimulation
 
  • Details

Pulse energy as a reliable reference for twitch forces induced by transcutaneous neuromuscular electrical stimulation

Journal
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Journal Volume
20
Journal Issue
4
Pages
574-583
Date Issued
2012
Author(s)
Chen C.-F.
WEN-SHIANG CHEN  
Chou L.-W.
Chang Y.-J.
Chen S.-C.
Kuo T.-S.
Lai J.-S.
DOI
10.1109/TNSRE.2012.2188305
URI
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84863740560&doi=10.1109%2fTNSRE.2012.2188305&partnerID=40&md5=1698db8b4f7ea43a9f8e88593f54ac67
https://scholars.lib.ntu.edu.tw/handle/123456789/481442
Abstract
Voltage-controlled neuromuscular electrical stimulation has been considered to be safer in noninvasive applications notwithstanding the fact that voltage-controlled devices purportedly generate forces less predictable than their current-controlled equivalents. This prompted us to evaluate relevant electrical parameters to determine whether forces induced by voltage-controlled stimuli were able to match to those induced by current-controlled ones, which tend to evoke forces that were more predictable. Force magnitudes corresponding to current- and voltage-controlled stimuli were aligned with respect to electric charge (equivalent to average current intensity) and electrical energy (equivalent to average power) of the same stimulation pulse to determine which provided a better coherence. Consistency of forces evaluated with energy was significantly (p < 0.001) better than that evaluated with electric charges, suggesting that electrically stimulated forces can be reliably predicted by monitoring the energy parameter of stimulation pulses. The above results appear to show that electrode-tissue impedance, a factor that makes charge and energy evaluations different, redefined the actual effects of current intensities in generating favorable results. Accordingly, novel schemes that track the energy (or average power) of a stimulation pulse may be used as a reliable benchmark to associate mechanical (force) and electrical (stimulation pulse) characteristics in transcutaneous applications of electrical stimulation.
SDGs

[SDGs]SDG7

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science