  4. SU‐FF‐T‐222: The Analysis of Confounding Factors in Volume Reconstruction of 3DCRT with Spiral Mode CT Simulation
 
  • Details

SU‐FF‐T‐222: The Analysis of Confounding Factors in Volume Reconstruction of 3DCRT with Spiral Mode CT Simulation

Journal
Medical Physics
Journal Volume
32
Journal Issue
6
Date Issued
2005
Author(s)
Wu, J.
WEN-YIH TSENG  
Chen, C.
CHUNG-MING CHEN  
DOI
10.1118/1.1997950
URI
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85024787724&doi=10.1118%2f1.1997950&partnerID=40&md5=fe0c42160a080b2bab82b915a113078b
https://scholars.lib.ntu.edu.tw/handle/123456789/485727
Abstract
Purpose: This study is to analyze the difference in reconstructing volume by using phantom model between various settings of axial-mode and spiral-mode computed tomography (CT) simulator for three dimensional conformal radiotherapy. Method and Materials: Three phantom balls with different diameters (5.1, 9.9, 12.2 cm) were scanned by a single-row detector CT simulator. The volumes of all phantom balls were reconstructed in the same system. The exactly calculated phantom ball volumes were the baselines as compared to the volumes by the conventional axial CT reconstruction. The reconstructed volumes from the axial-scanning-mode were compared with the corresponding settings of the spiral-scanning-mode in CT simulation, with four different Hounsfield thresholds, three different pitches (1, 1.5 and 2), and four different slice intervals (1, 2, 3 and 5 mm). Results: The larger slice width and HU threshold were associated with larger difference between the exactly calculated volumes and reconstructed volumes in axial CT mode. The volume losses were more than 5% for small phantom ball in all axial CT settings. The lowest HU threshold and slice width of less than 5 mm were needed to maintain the volume loss of less than 5% in medium and large balls. As compared to axial scanning, spiral scanning offered the volume reconstruction loss of less than 5% in almost all settings. The exceptions existed in the small phantom ball with the slice interval of 5 mm, spiral pitch of 1.5 and 2 at 50 HU, and slice interval of 5 mm, spiral pitch of 2 at 0 HU. Conclusion: Slice interval, spiral scanning pitch and HU threshold were the factors with the impact on the accurate estimation of volume reconstruction by spiral CT simulator. Spiral CT mode was feasible in most scanning settings with the acceptable volume reconstruction accuracy threshold of more than 95%.
SDGs

[SDGs]SDG11

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science