Abstract
The effect of metastable austenite on the hydrogen embrittlement (HE) of cold-rolled (30% reduction in thickness) 301 stainless steel (SS) was investigated. Cold-rolled (CR) specimens were hydrogen-charged in an autoclave at 300 or 450◦C under a pressure of 10 MPa for 160 h before tensile tests. Both ordinary and notched tensile tests were performed in air to measure the tensile properties of the non-charged and charged specimens. The results indicated that cold rolling caused the transformation of austenite into α′ and ε-martensite in the 301 SS. Aging at 450◦C enhanced the precipitation of M23C6 carbides, G, and σ phases in the cold-rolled specimen. In addition, the formation of α′ martensite and M23C6 carbides along the grain boundaries increased the HE susceptibility and low-temperature sensitization of the 450◦C-aged 301 SS. In contrast, the grain boundary α′-martensite and M23C6 carbides were not observed in the as-rolled and 300◦C-aged specimens.