標題: | Development of a computerized adaptive test for assessing balance function in patients with stroke | 作者: | I-PING HSUEH Chen J.-H. Wang C.-H. Chen C.-T. Sheu C.-F. Wang W.-C. Hou W.-H. CHING-LIN HSIEH |
公開日期: | 2010 | 卷: | 90 | 期: | 9 | 起(迄)頁: | 1336-1344 | 來源出版物: | Physical Therapy | 摘要: | Background. An efficient and precise measure of balance is needed to improve administration efficiency and to reduce the assessment burden for patients. Objective. The purpose of this study was to develop a computerized adaptive testing (CAT) system for assessing balance function in an efficient, reliable, and valid fashion in patients with stroke. Design. Two cross-sectional prospective studies were conducted. Setting. This study was conducted in the departments of physical medicine and rehabilitation in 6 hospitals. Patients. The participants were inpatients and outpatients who were receiving rehabilitation. Measurements. A balance item pool (41 items) was developed on the basis of predefined balance concepts, expert opinions, and field testing. The items were administered by 5 raters to 764 patients. An item response theory model was fit to the data, and the item parameters were estimated. A simulation study was used to determine the performance (eg, reliability, efficiency) of the Balance CAT. The Balance CAT and the Berg Balance Scale (BBS) then were tested on another independent sample of 56 patients to determine the concurrent validity and time needed for administration. Results. Seven items did not meet the model's expectations and were excluded from further analysis. The remaining 34 items formed the item bank of the Balance CAT. Two stopping rules (ie, reliability coefficient >0.9 or ?6 items) were set for the CAT. The simulation study showed that the patients' balance scores estimated by the CAT had an average reliability value of .94. The scores obtained from the CAT were closely associated with those of the full item set (Pearson r=.98). The scores of the Balance CAT were highly correlated with those of the BBS (Pearson r=.88). The average time needed to administer the Balance CAT (83 seconds) was only 18% of that of the BBS. Limitations. The convenience sampling of both samples may limit the generalization of the results. Further psychometric investigation of the Balance CAT is needed. Conclusion, The results provide strong evidence that the Balance CAT is efficient and has reliability and validity for patients with stroke. ? 2010 American Physical Therapy Association. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-77956898603&doi=10.2522%2fptj.20090395&partnerID=40&md5=d28a782c6bd109bce8569161d25e8958 https://scholars.lib.ntu.edu.tw/handle/123456789/504370 |
ISSN: | 0031-9023 | DOI: | 10.2522/ptj.20090395 | SDG/關鍵字: | aged; article; body equilibrium; computer assisted diagnosis; cross-sectional study; disability; female; human; male; methodology; middle aged; pathophysiology; physiology; prospective study; psychometry; stroke; validation study; Aged; Cross-Sectional Studies; Diagnosis, Computer-Assisted; Disability Evaluation; Female; Humans; Male; Middle Aged; Postural Balance; Prospective Studies; Psychometrics; Stroke |
顯示於: | 職能治療學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。