Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • Home
  • Organizations
  • Researchers
  • Research Outputs
  • Explore by
    • Organizations
    • Researchers
    • Research Outputs
  • Academic & Publications
  • Sign in
  • 中文
  • English
  1. NTU Scholars
  2. 醫學院
  3. 醫學系
Please use this identifier to cite or link to this item: https://scholars.lib.ntu.edu.tw/handle/123456789/512492
Title: Quantitative determination of isoniazid in biological samples by cation-selective exhaustive injection-sweeping-micellar electrokinetic chromatography
Authors: Tsai I.-L.
Liu H.-Y.
PING-HUNG KUO 
JANN-YUAN WANG 
LI-JIUAN SHEN 
CHING-HUA KUO 
Issue Date: 2011
Journal Volume: 401
Journal Issue: 7
Start page/Pages: 2205-2214
Source: Analytical and Bioanalytical Chemistry
Abstract: 
Tuberculosis (TB), an infectious disease caused by Mycobacterium tuberculosis, infects approximately one third of the current world population. Isoniazid is one of the most frequently used first-line anti-TB drugs. In this study, we developed a sensitive cation-selective exhaustive injection-sweeping- micellar electrokinetic chromatography method (CSEI-Sweep-MEKC) for analyzing isoniazid in human plasma. Parameters including acetonitrile (ACN) percentage in the separation buffer; the injection time, and concentration of the high-conductivity buffer; sodium dodecyl sulfate (SDS) concentration; phosphate concentration in the sample matrix; and the sample injection time were all optimized to obtain the best analytical performance. The optimal background electrolyte comprised 50 mM phosphate buffer, 100 mM SDS, and 15% ACN. Non-micelle background electrolyte, containing 75 mM phosphate buffer and 15% ACN, was first injected into the capillary, followed by a short plug of 200 mM phosphate (high-conductivity buffer). Run-to-run repeatability (n?=?3) and intermediate precision (n?=?3) of peak area ratios were found to be lower than 8.7% and 11.4% RSD, respectively. The accuracy of the method was within 98.1-106.9%. The limit of detection of isoniazod in human plasma was 9 ng mL -1. Compared with conventional MEKC, the enhancement factor of the CSEI-Sweep-MEKC method was 85 in plasma samples. The developed method was successfully used to determine isoniazid concentration in patient plasma. The results demonstrated that CSEI-Sweep-MEKC has the potential to analyze isoniazid in human plasma for therapeutic drug monitoring and clinical research. ? 2011 Springer-Verlag.
URI: https://www.scopus.com/inward/record.uri?eid=2-s2.0-80255135492&doi=10.1007%2fs00216-011-5285-8&partnerID=40&md5=95c019fce73a54e4a2b2f8a8a5c7af17
https://scholars.lib.ntu.edu.tw/handle/123456789/512492
ISSN: 1618-2642
DOI: 10.1007/s00216-011-5285-8
SDG/Keyword: Analytical performance; Back ground electrolyte; Biological samples; Cation-selective exhaustive injection; Clinical research; Electrokinetic chromatography; Enhancement factor; Human plasmas; Infectious disease; Injection time; Isoniazid; Limit of detection; Micellar electrokinetic chromatography; Mycobacterium tuberculosis; Peak area ratios; Phosphate buffers; Phosphate concentration; Plasma samples; Quantitative determinations; Run to run; Sample injection; Sample matrix; Separation buffers; Sodium dodecyl sulfate; Sweeping; Therapeutic drug monitoring; World population; Acetonitrile; Concentration (process); Electrodynamics; Electrolytes; Liquid chromatography; Optimization; Patient monitoring; Plasma (human); Plasmas; Positive ions; Sodium sulfate; Hydrazine; acetonitrile; acetonitrile derivative; buffer; cation; dodecyl sulfate sodium; isoniazid; tuberculostatic agent; article; chemistry; human; metabolism; micellar electrokinetic chromatography; micelle; Acetonitriles; Antitubercular Agents; Buffers; Cations; Chromatography, Micellar Electrokinetic Capillary; Humans; Isoniazid; Micelles; Sodium Dodecyl Sulfate; Mycobacterium tuberculosis
[SDGs]SDG3
Appears in Collections:醫學系

Show full item record

SCOPUSTM   
Citations

17
checked on Mar 27, 2023

WEB OF SCIENCETM
Citations

17
checked on Mar 19, 2023

Page view(s)

7
checked on Mar 27, 2023

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Sherpa Romeo網站查詢,以確認出版單位之版權政策。
    Please use Sherpa Romeo to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback