標題: | Multiphase CT angiography versus single-phase CT angiography: Comparison of image quality and radiation dose | 作者: | Yang C.-Y. YA-FANG CHEN CHUNG-WEI LEE Huang A. Shen Y. Wei C. HON-MAN LIU |
公開日期: | 2008 | 卷: | 29 | 期: | 7 | 起(迄)頁: | 1288-1295 | 來源出版物: | American Journal of Neuroradiology | 摘要: | BACKGROUND AND PURPOSE: Conventional CT angiography (CTA) is acquired during only a short interval in the arterial phase, which limits its ability to evaluate the cerebral circulation. Our aim was to compare the image quality and radiation dose of conventional single-phase CTA (SP-CTA) with a multiphase CTA (MP-CTA) algorithm reconstructed from a perfusion CT (PCT) dataset. MATERIALS AND METHODS: Fifty consecutive patients undergoing head CTA and PCT in 1 examination were enrolled. The PCT dataset was obtained with 40.0-mm-detector coverage, 5.0-mm axial thickness, 80 kilovolt peak (kVp), 180 mA, and 30 mL of contrast medium. MP-CTA was reconstructed from the same PCT dataset with an axial thickness of 0.625 mm by using a new axial reconstruction algorithm. A conventional SP-CTA dataset was obtained with 0.625-mm axial thickness, 120 kVp, 350 mA, and 60 mL of contrast medium. We compared image quality, vascular enhancement, and radiation dose. RESULTS: SP-CTA and MP-CTA of 50 patients (male/female ratio, 31/19; mean age, 59.25 years) were analyzed. MP-CTA was significantly better than SP-CTA in vascular enhancement (P = .002), in the absence of venous contamination (P = .006), and was significantly higher in image noise (P = .001). MP-CTA used less contrast medium than SP-CTA and could demonstrate hemodynamic information. The effective dose of MP-CTA was 5.73 mSv, which was equal to that in conventional PCT, and it was 3.57 mSv in SP-CTA. CONCLUSION: It is feasible that MP-CTA may provide both CTA and PCT results. Compared with SP-CTA, MP-CTA provides comparable image quality, better vascular enhancement, hemodynamic information, and more noise with less detail visibility with a lower tube voltage. The radiation dose of MP-CTA is higher than that of SP-CTA, but the dose can be reduced by altering the sampling interval. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/514704 | ISSN: | 0195-6108 | DOI: | 10.3174/ajnr.A1073 | SDG/關鍵字: | contrast medium; iopromide; adult; algorithm; article; clinical article; computed tomographic angiography; controlled study; dose response; female; head; hemodynamics; human; image quality; intermethod comparison; male; radiation dose; sex ratio; statistical significance; Adult; Aged; Carotid Stenosis; Cerebral Angiography; Cerebral Arterial Diseases; Cerebral Infarction; Contrast Media; Dose-Response Relationship, Drug; Feasibility Studies; Female; Humans; Image Processing, Computer-Assisted; Intracranial Aneurysm; Intracranial Arteriovenous Malformations; Iohexol; Male; Middle Aged; Moyamoya Disease; Phantoms, Imaging; Radiation Dosage; Sensitivity and Specificity; Tomography, Spiral Computed; Tomography, X-Ray Computed |
顯示於: | 醫學院附設醫院 (臺大醫院) |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。