https://scholars.lib.ntu.edu.tw/handle/123456789/516818
標題: | Removal torque of miniscrews used for orthodontic anchorage - A preliminary report | 作者: | YI-JANE CHEN Chen Y.-H. LI-DEH LIN JANE CHUNG-CHEN YAO |
公開日期: | 2006 | 卷: | 21 | 期: | 2 | 起(迄)頁: | 283-289 | 來源出版物: | International Journal of Oral and Maxillofacial Implants | 摘要: | Purpose: Implant anchors such as miniscrews and miniplates have been loaded immediately for anchorage during orthodontic treatment. The purpose of this study was to measure the removal torque of immediately loaded miniscrews after clinical usage and to determine the possible factors associated with this value. Materials and Methods: From 29 patients with malocclusions, 46 miniscrews were removed, and removal torque was measured with a torque gauge. Removal torque values were subjected to statistical analysis for possible association of different clinical characteristics. Results: The mean removal torque value was 1.10 kg·cm, and removal torques for 50% of the implants were greater than 0.89 kg·cm (8.7 N·cm). Removal torque values were significantly higher in the mandible than in the maxilla. The removal torques of 15-mm and 17-mm miniscrews were significantly higher than those of 13-mm miniscrews. Therefore, the site of implantation and miniscrew length were important factors associated with removal torque. However, there was no significant correlation between the removal torque value and age, gender, healing time, or time in function. Discussion: When miniscrews are used as anchorage for uprighting tipped molars, excessive torque in a counterclockwise direction may loosen them. From the measurements obtained in this investigation, miniscrews can sufficiently sustain an uprighting moment. Conclusion: The removal torque values of the majority of miniscrews in this study population when loaded immediately as orthodontic anchorage were greater than 0.89 kg·cm, and this was sufficient for these implants to fulfill their purpose as anchors in 3-dimensional tooth movements. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-33646254378&partnerID=40&md5=a94d05e44d7771830aec64c05c867fbd https://scholars.lib.ntu.edu.tw/handle/123456789/516818 |
ISSN: | 0882-2786 | SDG/關鍵字: | adolescent; adult; analysis of variance; article; bone screw; dental care; device removal; electronics; female; human; instrumentation; male; middle aged; molar tooth; orthodontics; periodontal disease; torque; Adolescent; Adult; Analysis of Variance; Bone Screws; Dental Stress Analysis; Device Removal; Female; Humans; Male; Middle Aged; Miniaturization; Molar; Orthodontic Anchorage Procedures; Tooth Movement; Torque |
顯示於: | 牙醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。