標題: | Intraocular pressure measurement with the noncontact tonometer through soft contact lenses | 作者: | Liu Y.-C. JEHN-YU HUANG I-JONG WANG FUNG-RONG HU YU-CHIH HOU |
公開日期: | 2011 | 卷: | 20 | 期: | 3 | 起(迄)頁: | 179-182 | 來源出版物: | Journal of Glaucoma | 摘要: | PURPOSE: To assess the accuracy of measuring intraocular pressure (IOP) through a soft contact lens (SCL) with different refractive powers using a noncontact tonometer (NCT). METHODS: Thirty-two healthy adult volunteers free of glaucoma or corneal disease participated in this study. IOP was measured in the right eyes without SCLs and with different lens powers, from -3.0 to -12.0 D as measured by NCT. IOP of the left eyes was also measured, as an internal control. Corneal curvature was measured in both eyes using an autokeratometer. Sixteen volunteers wore one brand of SCL (group A) and the other 16 wore a different brand, with 2 different curvatures (groups B and C). Statistical data were analyzed by SPSS using the Wilcoxon signed rank test for comparison of IOP readings and multiple linear regression analysis for the relationship among power of contact lenses, corneal power, and difference in IOP measurements. RESULTS: The difference in mean IOP between eyes without lenses and those with lenses was statistically significant in lens with -6.0 D and below in all 3 groups. The decrease in IOP significantly correlated with the refractive power of contact lenses in all 3 groups. The difference in IOP measurements was influenced by the mean K in group A but not in group B or C. There was no statistically significant difference in the IOP measurements in the left eyes or in the mean K between the right and left eyes. CONCLUSIONS: IOP measurement through myopic SCLs by NCT may be inaccurate and tends toward underestimation, especially in high myopic lenses. A strong relationship exists between IOP reduction and myopic lens power. ? 2011 Lippincott Williams & Wilkins, Inc. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-79952662622&doi=10.1097%2fIJG.0b013e3181aae90c&partnerID=40&md5=75643d5e9530d5593f50ce05234e15c6 https://scholars.lib.ntu.edu.tw/handle/123456789/522452 |
ISSN: | 1057-0829 | DOI: | 10.1097/IJG.0b013e3181aae90c | SDG/關鍵字: | adult; article; clinical assessment; controlled study; cornea curvature; data analysis; human; human experiment; intraocular pressure; keratometry; lens power; multiple linear regression analysis; normal human; optical resolution; pressure measurement; priority journal; refractive keratoplasty; soft contact lens; tonometer; Wilcoxon signed ranks test; Adult; Contact Lenses, Hydrophilic; Humans; Intraocular Pressure; Middle Aged; Myopia; Reproducibility of Results; Tonometry, Ocular; Young Adult |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。