標題: | Nonsurgical transvenous retrieval of fractured implantable central venous access device | 作者: | CHIEN-HUA HUANG WEN-JONE CHEN YI-LWUN HO CHAU-CHUNG WU Lee Y.-T. |
公開日期: | 1999 | 卷: | 98 | 期: | 4 | 起(迄)頁: | 265-270 | 來源出版物: | Journal of the Formosan Medical Association | 摘要: | Implantable central venous access devices (ICVADs) are commonly used in patients with cancer and chronic diseases. Fracture and distal embolization of an ICVAD fracture is rare. A total of 1,006 central venous access procedures using ICVADS were done in National Taiwan University Hospital from January 1994 to December 1996. ICVAD fractures were noted in five of these 1,006 cases. All the fractured catheters were retrieved successfully by nonsurgical transvenous methods. The clinical manifestations were nonspecific palpitation or chest pain. The fracture site was always on the crossover point of the clavicle and the first rib on chest radiography. A pinch-off mechanism was suspected, and supported by scanning microscopy imaging. A deformed and elliptical shape of the fractured catheter site resulted from repeated wear and tear by the movement of the clavicle and first rib and associated muscle groups. The clinical course was benign if early retrieval of the distal fractured catheter by snare loop was possible. A more lateral position by a subclavian approach or an axillary approach for central venous access may avoid this procedure-related complication. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/526630 | ISSN: | 0929-6646 | SDG/關鍵字: | adult; article; central venous catheterization; clavicle; clinical article; female; first rib; heart palpitation; human; implantation; male; prosthesis failure; radiography; thorax pain; Adult; Catheters, Indwelling; Clavicle; Equipment Failure; Female; Humans; Male; Methods; Middle Aged; Ribs |
顯示於: | 醫學院附設醫院 (臺大醫院) |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。