Multimode VCSEL Enables 42-GBaud PAM-4 and 35-GBaud 16-QAM OFDM for 100-m OM5 MMF Data Link

Journal
IEEE Access
Journal Volume
8
Pages
36963-36973
Date Issued
2020
Author(s)
Huang, C.-Y.
Wang, H.-Y.
Peng, C.-Y.
Tsai, C.-T.
Wu, C.-H.
GONG-RU LIN  
CHAO-HSIN WU  
DOI
10.1109/ACCESS.2020.2975127
URI
https://www.scopus.com/inward/record.url?eid=2-s2.0-85081132826&partnerID=40&md5=705c66df7719c810f4cdc41418068f20
https://scholars.lib.ntu.edu.tw/handle/123456789/555719
Abstract
By enhancing the differential gain and reducing the capacitance of the 850-nm multi-mode vertical cavity surface emitting laser (VCSEL) with an analog bandwidth beyond 25 GHz via the use of InGaAs/AlGaAs quantum wells and multiple oxide confinement layers, the transmission of directly encoded 4-level pulse amplitude modulation (PAM-4) data at 42 GBaud and 16-quadrature amplitude modulation orthogonal frequency division multiplexing (16-QAM OFDM) data at 35 GBaud are demonstrated. After passing through 100-m OM5 multimode fiber (MMF), the detailed comparison between the VCSELs designed with different aperture sizes of 5.5/7.5 �gm is performed. The 7.5-�gm-aperture VCSEL provides the higher power with larger quantum efficiency but exhibits the narrower 3-dB bandwidth and higher noise level than those of the 5.5-�gm-aperture VCSEL. Shrinking the oxide-confined aperture to 5.5 �gm assists the VCSEL to expand its 3-dB bandwidth to 25.2 GHz and suppresses its relative intensity noise to -135 dBc/Hz, which contributes to support the highest data rate up to 84 and 140 Gbit/s, respectively, for PAM-4 and 16-QAM OFDM data under forward error correction criterion at optical back-to-back condition. Even after transmitting through 100-m-long OM5-MMF, the allowable data transmission rate still remains at 80 Gbit/s for PAM-4 and 120 Gbit/s for 16-QAM OFDM with their receiving power penalty of 3.24 and 3.1 dB, respectively, when the data is carried by the 5.5-�gm-aperture VCSEL. Such a newly designed VCSEL structure promotes its allowable bandwidth to manifest the feasibility toward 50-GBaud per channel capacity for future data center applications.
SDGs

[SDGs]SDG7

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science