https://scholars.lib.ntu.edu.tw/handle/123456789/570555
標題: | Comparison of regular- and slope-configured dental implants placed in the edentulous ridge with height discrepancy: A pilot randomized controlled trial | 作者: | Tu C.-C. Wang S.-H. Hu C.-Y. Chen M.-H. Hsieh O. PO-CHUN CHANG |
關鍵字: | Alveolar ridge; Cytokines; Dental implants; Periodontium; Randomized controlled trial | 公開日期: | 2021 | 出版社: | Elsevier B.V. | 卷: | 120 | 期: | 6 | 起(迄)頁: | 1386-1393 | 來源出版物: | Journal of the Formosan Medical Association | 摘要: | Background/Purpose: Edentulous ridges with height discrepancies (RHDs) could jeopardize the outcome of implant placement. This study aimed at evaluating the outcomes of placing regular- and slope-configured implants in RHDs. Methods: Patients with >1 mm RHDs requesting implant rehabilitation were recruited and randomly assigned to regular- (control) or slope-configured (test) implant treatment using a submerged installation protocol. Thread exposure (TE) and implant stability quotient (ISQ) were evaluated during implant installation (S1) and uncovered surgery (S2), and marginal bone level (MBL) was evaluated after implant installation (T1) and uncovery (T3), and one year after implant placement (T4). Periodontal status and gingival crevicular fluid (GCF) biomarkers of adjacent teeth were evaluated before implant installation (T0), before uncovery (T2), and at T4. Peri-implant clinical status and peri-implant crevicular fluid (PICF) biomarkers of examined implants were evaluated at T4. Results: Nineteen patients with 17 control and 13 test implants were included. All of the implants survived with acceptable peri-implant health, and PICF biomarkers were at equivalent levels as GCF biomarkers of the adjacent teeth at T4. Compared with the control group, the test group showed reduced TE and equivalent ISQ at S1 and S2, and the loss of MBL was reduced at T4. Regarding the adjacent teeth, all periodontal parameters and GCF biomarkers were slightly decreased from T0 to T2, and the reductions in probing pocket depth and clinical attachment level were slightly greater at T4. Conclusion: Slope-configured implants maintained the implant-supporting structures and minimally altered periodontal status of the adjacent teeth in RHDs. ? 2020 |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85095759429&doi=10.1016%2fj.jfma.2020.10.024&partnerID=40&md5=1e7139c0b927c00b30a33c3984de87ac https://scholars.lib.ntu.edu.tw/handle/123456789/570555 |
ISSN: | 0929-6646 | DOI: | 10.1016/j.jfma.2020.10.024 | SDG/關鍵字: | amoxicillin; biological marker; chlorhexidine; interleukin 1; interleukin 1beta; mouthwash; neutrophil collagenase; paracetamol; adult; aged; alveolar ridge; Article; bone level; clinical article; clinical assessment; comparative study; cone beam computed tomography; controlled study; edentulousness; enzyme linked immunosorbent assay; female; gingivitis; human; male; outcome assessment; parameters; periodontal pocket depth; periodontium; pilot study; prospective study; prosthesis design; randomized controlled trial; survival; tooth; tooth implant; Dental Implants; Gingival Crevicular Fluid; Humans; Pilot Projects; Tooth |
顯示於: | 臨床牙醫學研究所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。