標題: | Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry - Preliminary Ex Vivo Investigation | 作者: | Huang C.-F.J Lin W.-L Hwang S.-C Yao C Chang H Kuo L.-W. Lin, Win-Li |
關鍵字: | Deconvolution;Extraction;Thermometers;Tissue;Deconvolution algorithm;High intensity focused ultrasound;Mean absolute error;Proof of concept;Regions of interest;Temperature estimation;Tissue inhomogeneity;Two sample t tests;Temperature distribution;ablation therapy;article;artifact;controlled study;deconvolution algorithm;ex vivo study;extraction;human;human tissue;intermethod comparison;magnetic resonance guided high intensity focused ultrasound;magnetic resonance thermometry;pork;proof of concept;algorithm;animal;biology;computer assisted diagnosis;imaging phantom;in vitro study;nuclear magnetic resonance imaging;pig;procedures;temperature;thermography;thermometry;thermotherapy;ultrasound surgery;ultrasound therapy;Algorithms;Animals;Computational Biology;Humans;Hyperthermia, Induced;Image Interpretation, Computer-Assisted;In Vitro Techniques;Magnetic Resonance Imaging;Phantoms, Imaging;Sus scrofa;Temperature;Thermography;Thermometry;Ultrasonic Surgical Procedures;Ultrasonic Therapy | 公開日期: | 2021 | 卷: | 2021 | 來源出版物: | Computational and Mathematical Methods in Medicine | 摘要: | Purpose. We present a novel background tissue phase removing method, called anatomical phase extraction (APE), and to investigate the accuracy of temperature estimation and capability of reducing background artifacts compared with the conventional referenceless methods. Methods. Susceptibility variance was acquired by subtracting pretreatment baseline images taken at different locations (nine pretreatment baselines are acquired and called ?1 to ?9). The susceptibility phase data ?S was obtained using the Wiener deconvolution algorithm. The background phase data ?T was isolated by subtracting ?S from the whole phase data. Finally, ?T was subtracted from the whole phase data before applying the referenceless method. As a proof of concept, the proposed APE method was performed on ex vivo pork tenderloin and compared with other two referenceless temperature estimation approaches, including reweighted ?1 referenceless (RW- ?1) and ?2 referenceless methods. The proposed APE method was performed with four different baselines combination, namely, (?1, ?5, ?2, ?4), (?3, ?5, ?2, ?6), (?7, ?5, ?8, ?4), and (?9, ?5, ?8, ?6), and called APE experiment 1 to 4, respectively. The multibaseline method was used as a standard reference. The mean absolute error (MAE) and two-sample t-test analysis in temperature estimation of three regions of interest (ROI) between the multibaseline method and the other three methods, i.e., APE, RW- ?1, and ?2, were calculated and compared. Results. Our results show that the mean temperature errors of the APE method-experiment 1, APE method-experiment 2, APE method-experiment 3, APE method-experiment 4, and RW- ?1 and ?2 referenceless method are 1.02°C, 1.04°C, 1.00°C, 1.00°C, 4.75°C, and 13.65°C, respectively. The MAEs of the RW- ?1 and ?2 referenceless methods were higher than that of APE method. The APE method showed no significant difference (p>0.05), compared with the multibaseline method. Conclusion. The present work demonstrates the use of the APE method on referenceless MR thermometry to improve the accuracy of temperature estimation during MRI guided high-intensity focused ultrasound for ablation treatment. ? 2021 Chien-Feng Judith Huang et al. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85113821371&doi=10.1155%2f2021%2f5566775&partnerID=40&md5=d47f9c7546ee172b799a12406f721f25 https://scholars.lib.ntu.edu.tw/handle/123456789/600296 |
ISSN: | 1748670X | DOI: | 10.1155/2021/5566775 |
顯示於: | 醫學工程學研究所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。