標題: | Field determination of inorganic mercury in seawaters by a portable dual-channel and purge-and-trap system with atomic fluorescence spectrometry | 作者: | Ang S.-J Chen Y.-S CHUN-MAO TSENG |
關鍵字: | cold vapour atomic fluorescence spectrometry;dual Au amalgamation;flow injection;Hg species;purge-and-trap;shipboard analysis;Chlorine compounds;Fluorescence;Fluorescence spectroscopy;Metals;Seawater;Spectrometry;Tin compounds;Analytical performance;Atomic fluorescence spectrometry;Certified reference materials;Environmental water;Field determination;Inorganic mercury;Reproducibilities;System optimisation;Mercury amalgams | 公開日期: | 2021 | 來源出版物: | International Journal of Environmental Analytical Chemistry | 摘要: | An on-line flow injection mercury analyser (FIMA) for inorganic mercury (Hg) analysis in environmental waters is presented. The FIMA is a portable dual-channel and purge-and-trap system combining aqueous reduction with stannous chloride (SnCl2), two-stage gold (Au) amalgamation, thermal desorption of Hg0 and final detection with cold vapour atomic fluorescence spectrometry (CVAFS). Simultaneous on-line operations of sample loading and analysis make analytical throughput and accuracy improved and contamination eliminated. Results of system optimisation and reliability regarding the determination of inorganic Hg2+ are described. Analytical performances of both channels were the same in terms of data reliability. Low procedural blanks were obtained from laboratory and field trip (?5 pg, n =?30). Excellent calibrations (r2?>?0.99) with a high precision and good stability (RSD <5%, n =?30) were obtained. Detection limits and reproducibility of the methods have been estimated as ?0.05 ng L?1 and <5% (0.5 ng L?1, n =?30). The system was finally validated by measurements comparison of the two channels (r2?>?0.98), and analysis of a certified reference material (coastal seawater BCR-579, recoveries 101?±?4%, n =?10). Overall, a sample throughput of ~10 samples per hour with two-channel detections of FIMA can be achieved. The onboard analysis of inorganic Hg species (e.g. elemental, reactive, and total Hg) in surface seawaters of the East China Sea (ECS) are also successfully achieved. The portable FIMA is fast, easy, and robust for reliable monitoring of Hg in natural seawaters. ? 2021 Informa UK Limited, trading as Taylor & Francis Group. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85114003201&doi=10.1080%2f03067319.2021.1967947&partnerID=40&md5=4146766bac52f23afbea661f88eac7b3 https://scholars.lib.ntu.edu.tw/handle/123456789/606362 |
ISSN: | 03067319 | DOI: | 10.1080/03067319.2021.1967947 |
顯示於: | 海洋研究所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。