https://scholars.lib.ntu.edu.tw/handle/123456789/629723
標題: | The Use of Distinctive Monoclonal Antibodies in FMD VLP- and P1-Based Blocking ELISA for the Seromonitoring of Vaccinated Swine | 作者: | Lee, Heng Wei Yang, Cheng Yao Lee, Ming Chang Chen, Shih Ping HUI-WEN CHANG IVAN-CHEN CHENG |
關鍵字: | blocking ELISA | foot-and-mouth disease virus | monoclonal antibodies | virus-like particles | 公開日期: | 1-八月-2022 | 出版社: | MDPI | 卷: | 23 | 期: | 15 | 來源出版物: | International Journal of Molecular Sciences | 摘要: | The serum neutralization (SN) test has been regarded as the “gold standard” for seroconversion following foot-and-mouth disease virus (FMDV) vaccination, although a high-level biosafety laboratory is necessary. ELISA is one alternative, and its format is constantly being improved. For instance, standard polyclonal antisera have been replaced by monoclonal antibodies (MAbs) for catching and detecting antibodies, and inactive viruses have been replaced by virus-like particles (VLPs). To the best of current knowledge, however, no researchers have evaluated the performances of different MAbs as tracers. In previous studies, we successfully identified site 1 and site 2 MAbs Q10E and P11A. In this study, following the established screening platform, the VLPs of putative escape mutants from sites 1 to 5 were expressed and used to demonstrate that S11B is a site 3 MAb. Additionally, the vulnerability of VLPs prompted us to assess another diagnostic antigen: unprocessed polyprotein P1. Therefore, we established and evaluated the performance of blocking ELISA (bELISA) systems based on VLPs and P1, pairing them with Q10E, P11A, S11B, and the non-neutralizing TSG MAb as tracers. The results indicated that the VLP paired with S11B demonstrated the highest correlation with the SN titers (R2 = 0.8071, n = 63). Excluding weakly positive serum samples (SN = 16–32, n = 14), the sensitivity and specificity were 95.65% and 96.15% (kappa = 0.92), respectively. Additionally, the P1 pairing with Q10E also demonstrated a high correlation (R2 = 0.768). We also discovered that these four antibodies had steric effects on one another to varying degrees, despite recognizing distinct antigenic sites. This finding indicated that MAbs as tracers could not accurately detect specific antibodies, possibly because MAbs are bulky compared to a protomeric unit. However, our results still provide convincing support for the application of two pairs of bELISA systems: VLP:S11B-HRP and P1:Q10E-HRP. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/629723 | ISSN: | 16616596 | DOI: | 10.3390/ijms23158542 |
顯示於: | 獸醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。