https://scholars.lib.ntu.edu.tw/handle/123456789/631008
標題: | The role of input imaging combination and ADC threshold on segmentation of acute ischemic stroke lesion using U-Net | 作者: | Li, Ya Hui Lin, Shao Chieh HSIAO-WEN CHUNG Chang, Chia Ching Peng, Hsu Hsia Huang, Teng Yi Shen, Wu Chung Tsai, Chon Haw Lo, Yu Chien Lee, Tung Yang Juan, Cheng Hsuan Juan, Cheng En Chang, Hing Chiu Liu, Yi Jui Juan, Chun Jung |
關鍵字: | Deep Learning | Diffusion Magnetic Resonance Imaging | Ischemic Stroke | Neural Networks, Computer | Retrospective Study | 公開日期: | 1-一月-2023 | 來源出版物: | European Radiology | 摘要: | Background: To evaluate the effect of the weighting of input imaging combo and ADC threshold on the performance of the U-Net and to find an optimized input imaging combo and ADC threshold in segmenting acute ischemic stroke (AIS) lesion. Methods: This study retrospectively enrolled a total of 212 patients having AIS. Four combos, including ADC-ADC-ADC (AAA), DWI-ADC-ADC (DAA), DWI-DWI-ADC (DDA), and DWI-DWI-DWI (DDD), were used as input images, respectively. Three ADC thresholds including 0.6, 0.8 and 1.8 × 10–3 mm2/s were applied. Dice similarity coefficient (DSC) was used to evaluate the segmentation performance of U-Nets. Nonparametric Kruskal–Wallis test with Tukey–Kramer post-hoc tests were used for comparison. A p <.05 was considered statistically significant. Results: The DSC significantly varied among different combos of images and different ADC thresholds. Hybrid U-Nets outperformed uniform U-Nets at ADC thresholds of 0.6 × 10–3 mm2/s and 0.8 × 10–3 mm2/s (p <.001). The U-Net with imaging combo of DDD had segmentation performance similar to hybrid U-Nets at an ADC threshold of 1.8 × 10–3 mm2/s (p =.062 to 1). The U-Net using the imaging combo of DAA at the ADC threshold of 0.6 × 10–3 mm2/s achieved the highest DSC in the segmentation of AIS lesion. Conclusions: The segmentation performance of U-Net for AIS varies among the input imaging combos and ADC thresholds. The U-Net is optimized by choosing the imaging combo of DAA at an ADC threshold of 0.6 × 10–3 mm2/s in segmentating AIS lesion with highest DSC. Key Points: • Segmentation performance of U-Net for AIS differs among input imaging combos. • Segmentation performance of U-Net for AIS differs among ADC thresholds. • U-Net is optimized using DAA with ADC = 0.6 × 10–3mm2/s. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/631008 | ISSN: | 09387994 | DOI: | 10.1007/s00330-023-09622-z |
顯示於: | 生醫電子與資訊學研究所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。