https://scholars.lib.ntu.edu.tw/handle/123456789/632132
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Hu C.-L | en-US |
dc.contributor.author | Cheng I.-C | en-US |
dc.contributor.author | Huang C.-H | en-US |
dc.contributor.author | Liao Y.-T | en-US |
dc.contributor.author | Lin W.-C | en-US |
dc.contributor.author | Tsai K.-J | en-US |
dc.contributor.author | Chi C.-H | en-US |
dc.contributor.author | Chen C.-W | en-US |
dc.contributor.author | Wu C.-H | en-US |
dc.contributor.author | Lin I.-T | en-US |
dc.contributor.author | Li C.-J | en-US |
dc.contributor.author | CHII-WANN LIN | en-US |
dc.creator | Hu C.-L;Cheng I.-C;Huang C.-H;Liao Y.-T;Lin W.-C;Tsai K.-J;Chi C.-H;Chen C.-W;Wu C.-H;Lin I.-T;Li C.-J;Lin C.-W. | - |
dc.date.accessioned | 2023-06-09T07:31:15Z | - |
dc.date.available | 2023-06-09T07:31:15Z | - |
dc.date.issued | 2021 | - |
dc.identifier.issn | 14248220 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85117062903&doi=10.3390%2fs21206789&partnerID=40&md5=34eaea2de98d32394a99e2151cffe201 | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/632132 | - |
dc.description.abstract | Electrical impedance tomography (EIT), a noninvasive and radiation-free medical imaging technique, has been used for continuous real-time regional lung aeration. However, adhesive electrodes could cause discomfort and increase the risk of skin injury during prolonged measurement. Additionally, the conductive gel between the electrodes and skin could evaporate in long-term usage and deteriorate the signal quality. To address these issues, in this work, textile electrodes integrated with a clothing belt are proposed to achieve EIT lung imaging along with a custom portable EIT system. The simulation and experimental results have verified the validity of the proposed portable EIT system. Furthermore, the imaging results of using the proposed textile electrodes were compared with commercial electrocardiogram electrodes to evaluate their performance. © 2021 by the authors. Licensee MDPI, Basel, Switzerland. | - |
dc.relation.ispartof | Sensors | - |
dc.subject | Belt; EIT; Portable electrical impedance tomography; Wearable textile electrode | - |
dc.subject.other | Adhesives; Biological organs; Electric impedance measurement; Electric impedance tomography; Electrodes; Medical imaging; Risk assessment; Textiles; Wearable technology; 'Dry' [; Conductive gels; Electrical impe dance tomography (EIT); Medical imaging techniques; Portable electrical impedance tomography; Real- time; Signal quality; Skin injuries; Textile electrodes; Wearable textile electrode; Electric impedance; electrode; electronic device; impedance; textile; tomography; Electric Impedance; Electrodes; Textiles; Tomography; Wearable Electronic Devices | - |
dc.title | Dry wearable textile electrodes for portable electrical impedance tomography | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.3390/s21206789 | - |
dc.identifier.pmid | 34696002 | - |
dc.identifier.scopus | 2-s2.0-85117062903 | - |
dc.relation.journalvolume | 21 | - |
dc.relation.journalissue | 20 | - |
item.cerifentitytype | Publications | - |
item.openairetype | journal article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.grantfulltext | none | - |
item.fulltext | no fulltext | - |
crisitem.author.dept | Biomedical Electronics and Bioinformatics | - |
crisitem.author.dept | Applied Mechanics | - |
crisitem.author.dept | Biomedical Engineering | - |
crisitem.author.dept | Electrical Engineering | - |
crisitem.author.orcid | 0000-0002-8721-3441 | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
crisitem.author.parentorg | College of Engineering | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | College of Engineering | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
顯示於: | 電機工程學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。