https://scholars.lib.ntu.edu.tw/handle/123456789/635307
標題: | Occupational radiation dose and protection to the eye lens for interventional cardiology operators | 作者: | Lian, Meng En Wu, Guan Yi Chao, Min Fang Wang, Chong Sheng Miao, Hsiao Chien Tsai, Ming Sung MU-YANG HSIEH Chen, Yeh Peng Chu, Chun Yuan Chang, Szu Li Tsai, Hui Yu |
關鍵字: | Eye lens dose | Interventional cardiology | Lead glasses | Personal dose equivalent | Radiation protection | 公開日期: | 1-六月-2022 | 卷: | 154 | 起(迄)頁: | 106778 | 來源出版物: | Radiation Measurements | 摘要: | Objectives: Interventional professionals tend to receive extended radiation exposure given the complexity and machine settings of procedures in interventional cardiology departments, resulting in a high eye lens dose. This study developed a method for estimating the occupational radiation dose to the eye lens based on the personal dose equivalent to the skin at 0.07-mm depth [Hp(0.07)] obtained using an over-apron dose badge, investigated whether glasses with lateral shielding but a thin Pb-equivalent material could adequately protect the eye lens from radiation in clinical situations, and identified factors affecting the occupational radiation dose to the eye lens. Methods: The occupational radiation dose was prospectively measured using dosimeters near the eye and over the lead apron at the collar level in 26 interventional professionals performing 444 procedures in interventional cardiology departments. Type A (0.07-mm front and lateral Pb equivalence) and type B (0.5-mm front Pb equivalence and 0.25-mm lateral Pb equivalence) glasses were worn by the operators during operation to protect the eye lens. Results: The median personal dose equivalent to the eye lens at 3-mm depth [Hp(3)/dose area product (DAP)] of the primary operator was the highest (7.6 μSv/Gycm2) for upper limb percutaneous transluminal angioplasty among all examined procedures. The secondary operator's median Hp(3)/DAP values ranged from 17% to 41% of that of the primary operator. The median Hp(3)/DAP values did not significantly differ between the primary operators wearing type A glasses and those wearing type B glasses for percutaneous coronary intervention or diagnostic cardiology studies (all p > 0.05). The Pearson correlation test results revealed significant positive correlations between the Hp(3) and Hp(0.07). The estimated annual Hp(3) values ranged from 3.3 ± 0.6 to 62.4 ± 8.3 mSv and from 6.0 to 8.0 ± 4.6 mSv for the cardiologists and radiographers, respectively. Conclusions: The Hp(3) value can be estimated from the Hp(0.07) value obtained using an over-apron dose badge at the collar level. Glasses with 0.07-mm front and lateral Pb equivalence provide satisfactory radiation protection to the eye lens. Regularly using appropriate radiation-protective lead glasses, adopting small angles for left anterior oblique projections, and undertaking moderate workloads are highly recommended to prevent cardiologists from receiving excessive radiation doses to the eye lens. |
URI: | https://www.scopus.com/record/display.uri?eid=2-s2.0-85129520487&doi=10.1016%2fj.radmeas.2022.106778&origin=inward&txGid=160788d3554af46855c04145637ede7a https://scholars.lib.ntu.edu.tw/handle/123456789/635307 |
ISSN: | 13504487 | DOI: | 10.1016/j.radmeas.2022.106778 |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。