Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider
Journal
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
1055
Start Page
168464
ISSN
0168-9002
Date Issued
2023-10
Author(s)
Abstract
We describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from −3.7 to 3.8 and two hadronic calorimeters covering a combined range of −1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.
Subjects
Calorimetry
ECCE
Electron ion collider
Tracking
SDGs
Publisher
Elsevier BV
Type