  4. High-Selectivity Nonenzymatic Creatinine Sensor Using Electrografted Ionic Liquid and Nafion for Reliable Clinical Diagnostics
 
  • Details

High-Selectivity Nonenzymatic Creatinine Sensor Using Electrografted Ionic Liquid and Nafion for Reliable Clinical Diagnostics

Journal
ACS Sensors
Journal Volume
10
Journal Issue
8
Start Page
6020
End Page
6028
ISSN
23793694
Date Issued
2025-08-22
Author(s)
Lin, Shih-Hao
Wang, Jing-Chun
ZONG-HONG LIN  
Kao, Fu-Cheng
Wang, Hsiang-Yu
DOI
10.1021/acssensors.5c01503
URI
https://www.scopus.com/record/display.uri?eid=2-s2.0-105013870709&origin=resultslist
https://scholars.lib.ntu.edu.tw/handle/123456789/732112
Abstract
The rapid and accurate detection of creatinine is essential for monitoring kidney function and diagnosing renal impairments. Nonenzymatic catalysts have been used to improve sensitivity and reduce environmental susceptibility in creatinine detection. However, limited selectivity hinders their broader application in practical scenarios. This study introduced a novel nonenzymatic creatinine sensor that utilized copper(II) oxide as a catalyst, incorporating styrenyl-triphenylphosphonium-based ionic liquid (STPP-IL) and Nafion on the electrode surface to enhance selectivity and minimize interference. Electrografting technique ensured uniform STPP-IL coverage on the electrode, as confirmed by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). The modified creatinine sensors demonstrated a detection range from 1.5 to 800 μM with low standard error and high sensitivities in the presence of interferents. Notably, creatinine levels in the artificial and natural human sweat were selectively quantified using the proposed sensor, supporting its potential for clinical applications. The sensors retained over 90% of their initial current response after 40 days of storage. Additionally, reproducibility experiments demonstrated a relative error of 1.3% across five independent sensors. These results show the sensor’s enhanced selectivity, stability, and reproducibility, making it a promising alternative for reliable creatinine detection in point-of-care tests.
Subjects
creatinine
CuONPs
electrografting
Nafion
styrenyl-triphenylphosphonium-based ionic liquid
SDGs

[SDGs]SDG3

Publisher
American Chemical Society
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science